Cable Guidance

Observant Support

Created: ; updated: .

The following illustrates the cabling used to connect supported devices to an Observant Telemetry Field Units. Each illustration may be printed and downloaded as a PDF file.

 

C3 Device Cabling

PDF available for printing and downloading here.

 

C3 Device Cable

Part #00774, the C3 to device cable (formerly DTC) diagram including wire colors and pin assignments can be found here

Solo Device Cabling 

PDF available for printing and downloading here.

 

Connector Identification

PDF available for printing and downloading here.

Conduit
Conduit should always be used for outdoor installations, cabling should never be directly exposed to the elements. We recommend that standard gray solid electrical conduit and fittings be used, orange heavy duty conduit is not UV stable so should not be used above ground. 25mm should be used to allow threading of EN3 connectors.
Where conduit opens to the environment it should be plugged with wadding or putty.
Flexible conduit is not recommended unless it is specifically rated for exterior use (ie. has UV protection).