Table — Device Cabling to Solo Field Unit Ports — Color Codes

Larry Pitts

Created: ; updated: .

Solo Cabling Details

Note: whenever possible, a device’s associated Tech Note should be consulted for installation information. In this table, available Tech Notes are linked to the device name. If there is no Tech Note, then the device is linked to its relevant Product Support Page.

All wire-to-wire junctions must be done via the supplied junction boxes.

Device

Device
Wire Colors

Solo Input
Accessory Cable
Wire Colors

Function

Davis Rain Gauge 

Red

Brown (Input 1)
or Blue (Input 2)

Signal

Green

Black

Ground

Flow Sensor

 

Red or White (typical)

Brown

Signal for input 1

Black

White

Ground

Red or White (typical)

Blue

Signal for input 2

Black

Black

Ground

Elektronic EE071   

Brown

Brown

Power for sensor

Blue

White

RS-485A

White

Blue

RS-485B

Black

Black

Ground

Gray

Not connected

Not connected

Senix Level Sensor

Brown

Brown

Power for sensor

Yellow

White

RS-485A

Grey

Blue

RS-485B

Blue

Black

Ground

Decagon VP4

White

Brown

Power for sensor

Red

Blue

SDI-12

Bare

Black

Ground

Decagon GS3

White

Brown

Power for sensor

Red

Blue

SDI-12

Bare

Black

Ground

Stephens Hydra Probe

Red

Brown

Power for sensor

Blue

Blue

SDI-12

Black

Black

Ground

EnviroPro

Red

Brown

Power

Blue

Blue

SDI-12

Black

Black

Ground

Schneider OsiSense

Brown

Brown

Supply

Blue

Black

Return

Aqua Blu 

Brown

Brown

Power for sensor

Blue

Blue

SDI-12

Yellow

Not connected

Not connected

Green/Yellow

Black

Ground

Aqua Check

Brown

Brown

Power for sensor

Blue

Blue

SDI-12

Green/Yellow

Black

Ground

 

 

 